PTP Acquisition Gate Time Low

The PTP acquisition gate time low feature specifies the lower 32 bits of the gate time for precision time protocol (PTP) acquisition, completing the timestamp for precise control over the start of image acquisition in conjunction with the PTP acquisition gate time high feature.

Note: This feature’s value limits are influenced by other features, so you must recheck the values after adjusting related features.

See also:

PtpAcquisitionGateTimeLow node

  • Access mode: Read/Write
  • Node type: Uint32

You can use the eSDK API functions to:

  • get and set the node’s current value, and
  • get the node’s minimum and maximum values, and the node’s value increments.

For more information about related features, see Acquisition Control Features.